Jump to: navigation, search

Difference between revisions of "Mellanox-Neutron-Kilo-Redhat-Ethernet"

(SDN Mechanism Driver)
 
(13 intermediate revisions by the same user not shown)
Line 1: Line 1:
= SR-IOV Configuration =
+
=Ethernet Configuration with Mellanox=
= SDN Mechanism Driver =
+
=SR-IOV Networking in OpenStack Kilo=
= Ceilometer =
+
OpenStack Juno added inbox support to request VM access to virtual network via SR-IOV NIC. With the introduction of SR-IOV based NICs, the traditional virtual bridge is no longer required. Each SR-IOV port is associated with a virtual function (VF). SR-IOV ports may be provided by Hardware-based Virtual Ethernet Bridging (HW VEB); or they may be extended to an upstream physical switch (IEEE 802.1br).
 +
There are two ways that SR-IOV port may be connected:
 +
* directly connected to its VF
 +
* connected with a macvtap device that resides on the host, which is then connected to the corresponding VF
 +
 
 +
==Configuration==
 +
[[SR-IOV-Passthrough-For-Networking|Configure SR-IOV]]
 +
 
 +
==SDN Mechanism Driver==
 +
[https://community.mellanox.com/docs/DOC-2155 SDN Mechanism Driver] allows NEO to configure dynamically VLANs on the Mellanox Switches.
 +
Further Reading
 +
* [http://www.mellanox.com/page/products_dyn?product_family=220&mtag=mellanox_neo NEO]
 +
* [http://www.mellanox.com/page/ethernet_switch_overview Mellanox Switches]
 +
* [https://community.mellanox.com/docs/DOC-2251 SDN Mechanism Driver]
 +
 
 +
==Ceilometer==
 +
The Mellanox Ceilometer SR-IOV module allows the OpenStack Ceilometer to collect measurements of SR-IOV counters.
 +
 
 +
More details about applying Mellanox Ceilometer module can be found [https://community.mellanox.com/docs/DOC-2145 here]

Latest revision as of 08:48, 22 July 2015

Ethernet Configuration with Mellanox

SR-IOV Networking in OpenStack Kilo

OpenStack Juno added inbox support to request VM access to virtual network via SR-IOV NIC. With the introduction of SR-IOV based NICs, the traditional virtual bridge is no longer required. Each SR-IOV port is associated with a virtual function (VF). SR-IOV ports may be provided by Hardware-based Virtual Ethernet Bridging (HW VEB); or they may be extended to an upstream physical switch (IEEE 802.1br). There are two ways that SR-IOV port may be connected:

  • directly connected to its VF
  • connected with a macvtap device that resides on the host, which is then connected to the corresponding VF

Configuration

Configure SR-IOV

SDN Mechanism Driver

SDN Mechanism Driver allows NEO to configure dynamically VLANs on the Mellanox Switches. Further Reading

Ceilometer

The Mellanox Ceilometer SR-IOV module allows the OpenStack Ceilometer to collect measurements of SR-IOV counters.

More details about applying Mellanox Ceilometer module can be found here