Difference between revisions of "Cinder/Tegile"
< Cinder
(Adding info page for Tegile Driver) |
(Adding more ini options) |
||
Line 17: | Line 17: | ||
[tegileISCSI] | [tegileISCSI] | ||
+ | volume_backend_name = tegileISCSI | ||
volume_driver = cinder.volume.drivers.tegile.TegileISCSIDriver | volume_driver = cinder.volume.drivers.tegile.TegileISCSIDriver | ||
+ | san_ip = 10.68.130.130 | ||
+ | san_login = user | ||
+ | san_password = password | ||
tegile_default_pool = tegilepool | tegile_default_pool = tegilepool | ||
tegile_default_project = tegileciiscsi | tegile_default_project = tegileciiscsi |
Latest revision as of 00:44, 5 January 2016
Tegile Cinder Driver Information
The Cinder driver for Tegile IntelliFlash Array is part of Mitaka release. The driver supports iSCSI and FC protocols.
The Tegile driver introduces 2 addition configuration options:
- tegile_default_pool
- Default pool to create and manage volumes, if none is passed on the Tegile driver by Cinder Scheduler.
- tegile_default_project
- Default project where newly created volumes are going to be placed. Projects provide a mechanism to groups LUNs and shares in Tegile IntelliFlash arrays.
Example in /etc/cinder/cinder.conf:
[default]
enabled_backends=tegileISCSI
default_volume_type=tegileISCSI
[tegileISCSI]
volume_backend_name = tegileISCSI
volume_driver = cinder.volume.drivers.tegile.TegileISCSIDriver
san_ip = 10.68.130.130
san_login = user
san_password = password
tegile_default_pool = tegilepool
tegile_default_project = tegileciiscsi
use_multipath_for_image_xfer = True
enforce_multipath_for_image_xfer = true