Jump to: navigation, search

Difference between revisions of "Cinder/Tegile"

(Adding info page for Tegile Driver)
 
(Adding more ini options)
 
Line 17: Line 17:
  
 
[tegileISCSI]         
 
[tegileISCSI]         
 +
volume_backend_name = tegileISCSI
 
volume_driver = cinder.volume.drivers.tegile.TegileISCSIDriver
 
volume_driver = cinder.volume.drivers.tegile.TegileISCSIDriver
 +
san_ip = 10.68.130.130
 +
san_login = user
 +
san_password = password
 
tegile_default_pool = tegilepool
 
tegile_default_pool = tegilepool
 
tegile_default_project = tegileciiscsi
 
tegile_default_project = tegileciiscsi

Latest revision as of 00:44, 5 January 2016

Tegile Cinder Driver Information

The Cinder driver for Tegile IntelliFlash Array is part of Mitaka release. The driver supports iSCSI and FC protocols.

The Tegile driver introduces 2 addition configuration options:

tegile_default_pool
Default pool to create and manage volumes, if none is passed on the Tegile driver by Cinder Scheduler.
tegile_default_project
Default project where newly created volumes are going to be placed. Projects provide a mechanism to groups LUNs and shares in Tegile IntelliFlash arrays.

Example in /etc/cinder/cinder.conf:

[default]
enabled_backends=tegileISCSI
default_volume_type=tegileISCSI

[tegileISCSI]        
volume_backend_name = tegileISCSI
volume_driver = cinder.volume.drivers.tegile.TegileISCSIDriver
san_ip = 10.68.130.130
san_login = user
san_password = password
tegile_default_pool = tegilepool
tegile_default_project = tegileciiscsi
use_multipath_for_image_xfer = True
enforce_multipath_for_image_xfer = true